The SEP series products are the latest compact and easy-to-use protein chromatography systems. Its unique design utilizes a dual-valve gradient mechanism to provide a versatile and cost effective solution to address applications in the development labs. It is primarily used for laboratory-level process research and method development, catering to the purification of target products such as proteins, antibodies, vaccines, nucleic acids, and diagnostic materials ranging from micrograms to tens of grams.
Technical Features
Streamlined design with a simple and flexible configuration, making it easy to get started.
One key arrangement of the pipeline, more tidy arrangement.
Quick start, pause button, more convenient operation.
Detachable tray design, leak-proof safer, easier to clean.
The UV detector is fully enclosed and anti-interference.
Large valve head design, pipeline disassembly is more convenient.
pH valves provide multiple flow path options for calibration and storage without disassembly.
PURfect P® software has built-in DOE and Scouting functions for easier conditional screening.
Application
Monoclonal antibody
Recombinat protein
Vaccines
Biochemical drug
Antibiotics
Natural products
Polysaccharides
Model | SEP-025 |
System pump | plunger pump, bioinert PEEK material, provides stable while precise flow rates |
Flow rate range | 0.01-25 ml/min |
System pressure rate | 0-10 MPa (100bar, 1450psi) |
Mixer | Magnetic stirring dynamic mixer, standard size: 2ml |
Flow rate accuracy | ±1.2% |
Flow rate precision | RSD<0.5% |
Supported elution | Isocratic/ramp/step gradient, in-process modification available |
UV detector | Option (1) F2-Default 260 & 280 nm detector, detecting both channels simultaneously; Option (2) V2-Detects 2 wavelengths at the same time, wavelength range: 200nm-400nm; Option (3) V4-Detects 4 wavelengths at the same time, wavelength range: 200nm-400nm; Option (4) V6-Detects 4 wavelengths at the same time, wavelength range: 200nm-600nm; Option (5) V8-Detects 4 wavelengths at the same time, wavelength range: 200nm-800nm |
Wavelength precision/repeatability | ±1nm / ±0.5nm |
UV noise / drift | 0.16 mAu(1s)/ 1 mAu/h |
Conductivity sensor | 0.001-999.99 mS/cm, precision ±0.1 mS/cm or ±2% |
Temperature sensor | 0-100℃, precision±1℃ |
Chromatography Workstation | PURfect P® advanced chromatography workstation for Win10 operating system |
Installation toolkit | PEEK / PTFE pipe, installation manual, user manual, tube connector, column clip, back-pressure valve, pre-column filter, 1 ml quantitative loop, common tools, etc |
Inlet valve | Four buffer inlets, A!-A2, B1-B2 |
Automatic sample injection valve | Load/Inject/Waste mode |
pH valve (optional) | 0 - 14, precision ±0.1 (2-12) |
Column-position valve (optional) | Single valve with 5 column positions; Column, Bypass, reverse flush functions |
Collection valve (optional) | Eight outlets(1 waste, 7 collection outlets) |
Fraction collector (optional) | Small size, flexible collection methods, can place the same or different specifications of the collection bracket side by side, automatically identify the collection rack. |
13mm collection rack: 1 x13mm test tube rack, 90 x 5ml test tubes | |
16mm collection rack: 1 x 16mm test tube rack, 60 x 15ml test tubes | |
28mm collection rack: 1 x 28mm test tube rack, 21 x 50ml test tubes | |
96-well plate collection rack: 1×96-well plate collection rack , containing four deep-well 96-well plates | |
Material | PEEK, Ti, PTFE |
System power | 220VAC/400W |
Instrument weight (gross weight) | 50kg |
Dimension (W*H*D) | 420mm*523mm*578mm |