The SCG-P-300's powerful performance and flexible capabilities are ready for all your needs.
Applications
●Monoclonal antibody
●Recombinat protein
●Vaccines
●Biochemical drug
●Antibiotics
●Natural products
●Polysaccharides
Performance
Dynamic mixer:5ml mixing chamber
Variety of UV detector module options. External fiber optic flow cell.
Conductivity detector:0-999.99mS/cm, temperature compensation possible.
Technical Features
• SCG-P-30 can satisfy milligram level purification need; SCG-P-100 can satisfy gram level purification need; SCG-P-300 can satisfy further scale up needs.
• Carefully designed flow path to minimize the dead volume.
• More add-on expandability available for external valves or future upgrades.
• Powerful SCG operation software offer intuitive and flexible method editor, system controller and data analysis tool. Please note that the software is free for upgrade during the product lifetime.
• Can work with various brand columns from domestic or international vendors.
• Can fit in regular chromatography refrigerator.
• Flexible flow path add-on and sample pump add-on available.
• Sample pump add-on available.
Model | SCG-P-300 |
System pump | Imported two duo plunger pump, bioinert PEEK material, provides stable while precise flow rates |
Flow rate range | 0.01-300 ml/min |
System pressure rate | 0-6.8 MPa(68bar, 1000psi) |
Mixer | 5ml in-line mixer |
Flow rate accuracy | ±2% |
Flow rate precision | RSD<0.5% |
Supported elution | Isocratic/ramp/step gradient, in-process modification available |
UV detector | Option1)Default 260 & 280 nm imported detector, detecting both channels simultaneously. Wavelengths customizable when ordering, including 2.0mm external circulation pool |
Option2)200 - 400 nm imported detector, detecting both channels simultaneously, including 2.0mm external flow cell | |
Option3)200 - 400 nm imported detector, detecting four channels simultaneously, including 2.0mm external flow cell | |
Option4)200 - 600 nm imported detector, detecting four channels simultaneously, including 2.0mm external circulation pool | |
Option5)190 - 840 nm imported detector, detecting four channels simultaneously, including 2.0mm external circulation pool | |
Wavelength precision/repeatability | ±1nm / ±0.5nm |
UV noise / drift | 0.16 mAu(1s)/ 1 mAu/h |
Conductivity sensor | 0.001-999.99 mS/cm, precision ±0.1 mS/cm or ±2% |
Temperature sensor | 0-100℃, precision±1℃, can compensate conductivity/pH result automatically |
pH sensor | 0 - 14, precision ±0.1 (2-12) |
In-line bubble detector | Control operation flow via detecting air bubbles in the pipeline |
Refractive index detector | Flow rate range: 1-50 ml/min, flow cell volume: 8 μL, assay range: 2.5- 5120 μRIU |
Multi-channel mobile phase selection module | A/B pumps available in 1 or 6 Buffer each |
Automatic sample injection valve | Software control, automatically injection while switching between Load/Inject/Waste mode |
Sample pump | 0.1 – 300 ml/min |
Sample selection valve | Supports 7 sample inlets, one buffer, biocompatible |
Column-position valve module | Option1)Column-position B valve:support for Column and ByPass functions Option2)Column-position C valve: support direct/reverse column and bypass flow path(Pressure resistance:2Mpa) Option3)3-column selection module:Support at most 3 columns in-line, controlled by software while support bypass.(Pressure resistance:250psi) |
Forward and reverse flush valves:3 column valves are required for forward and reverse flushing of the chromatography column. | |
Pre/post column pressure monitoring module | Check the pre-and post-column pressure |
Collection valve | Six-channel bulk collection valve |
SCG Chromatography Workstation | Chromatography Workstation Software:in-house designed operation software |
Installation toolkit | PEEK / PTFE pipe, installation manual, user manual, pipe joints, column clip, Flow restrictor, precolumn filter, 1 ml quantitative loop, common tools, etc |
Solvent tray | The instrument come with a solvent tray on the top, access easy while saving space |
Column supports | Can hold 1ml, 5ml, ID: 10mm, 16mm, 26mm, 50mm columns |
Component Collector | FC-S2 component collector,including two racks. |
Small size, flexible collection methods, can place the same or different specifications of the collection bracket side by side, automatically identify the collection rack. | |
13mm collection rack:1 x13mm test tube rack, 90 x 5ml test tubes | |
16mm collection rack:1 x 16mm test tube rack, 60 x 15ml test tubes | |
28mm collection rack:1 x 28mm test tube rack, 21 x 50ml test tubes | |
96-well plate collection rack:1×96-well plate collection rack, containing four deep-well 96-well plates | |
Wireless monitoring modules | Wireless mobile terminal monitoring module |
Sample contact material list | PEEK, Stainless Steel, PPS, PTFE |
AC input/ power rating | 220VAC/400W |
Instrument weight (gross weight) | 72kg |
Dimension (W*H*D) | 590mm*740mm*530mm |
Please enter your e-mail address and we will send you the User’s Manual ASAP
If you have any needs, please fill out the form below and we will contact you as soon as possible.
SCG-P has high precision bio-inert piston pump, which adopts pressure compensation technology with low pulsation and high infusion accuracy.
The SCG-Phf system is designed to meet the pilot-scale and small-scale production need.